Flat Feet Research - Flatfoot, Fallen Arches, Children, Treatment, Arthrodesis

Flat Feet Research Today is a free monthly online journal that collates and summarizes the latest research about Flat Feet, including details on flatfoot, fallen arches, children, treatment, arthrodesis.


Flat Feet Research Today

Home

View Latest Issue

Information About Flat Feet

Books on Flat Feet

Advertising in Research Today

View Other Research Today Publications



Accuracy over space and time of computer-assisted fluoroscopic navigation in the lumbar spine in vivo.

QuiƱones-Hinojosa A, Robert Kolen E, Jun P, Rosenberg WS, Weinstein PR

Department of Neurological Surgery, University of California, San Francisco, USA. quinones@post.harvard.edu

OBJECTIVE: The integration of digital image-guided surgical navigation with C-arm fluoroscopy, known as virtual fluoroscopy (VF), has been shown to enhance the safety of spine surgery in vitro. Few clinical studies have assessed the accuracy of VF during actual spinal surgery, and no studies have investigated variations in accuracy over the course of a series of measurements obtained during operative cases. We sought to study the intraoperative accuracy of VF over time and space during lumbar pedicle screw placement in human patients. METHODS: Fluoroscopic images of the lumbar spine were obtained, calibrated, and saved to the Stealth Station (FluoroNav) on seven patients undergoing lumbar fusion surgery. The tracking arc was attached to an exposed lumbar spinous process, which was designated the index level. With use of anatomic surface irregularities in the laminae and spinous processes, several points were identified and registered on three different vertebrae directly adjacent to the index level vertebra. Every 15 minutes, throughout the operative case, the probe was brought to each point and the apparent distance from the original location recorded (as measured by the FluoroNav system). Measurements were collected from three vertebral levels adjacent to the index level over a time course of 120 minutes during the operation. RESULTS: At the index, index +1, index +2, and index +3 levels, 89%, 81%, 92%, and 64% of measurements were within <2 mm, whereas 97%, 96%, 97%, and 91% were within <3 mm, respectively. At 15, 30, 45, 60, 75, 90, 105, and 120 minutes, 96%, 89%, 85%, 61%, 85%, 90%, 93%, and 50% of measurements were within <2 mm, whereas 100%, 93%, 100%, 83%, 100%, 90%, 100%, and 100% of measurements were within <3 mm, respectively. The error in millimeters tended to increase as the distance from the index level increased (R = 0.19, P < 0.05) and as operative time increased (R = 0.26, P < 0.01). Calibration studies of intraoperative VF (IoVF) in the lumbar spine documented a reasonable degree of accuracy. The majority of sequential measurements obtained during IoVF in the lumbar spine were within an error range of <3 mm. CONCLUSIONS: Our results suggest that the use of VF is a reliable method of verifying the use of anatomic and/or radiographic landmarks for guidance during lumbar pedicle screw placement.

Published 8 June 2006 in J Spinal Disord Tech, 19(2): 109-13.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Flat Feet Research Today. All Rights Reserved.



Flat Feet Research Today Archive:

Volume 1 (2005)
  Issue 1 (October)
  Issue 2 (November)
  Issue 3 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)



Flat Feet Books

Two-Story Homes: 450 Designs for 1 1/2 and 2 Stories : 1,500 to 6,000 Square Feet

Two-Story Homes: 450 Designs for 1 1/2 and 2 Stories : 1,500 to 6,000 Square Feet